| Trade Name: ASTRO ACOUSTIC VENT SLEEVE Fire Rated Vent Sleeve |
|||||||||||||||||
| A fire rated Vent Sleeve for ventilation ducts. Restores and maintains integrity of 30 & 60 minute fire rated ceilings Provides an effective acoustic barrier between fan / vent and ceiling Easy to retro fit into existing fans / vents Lightweight and can be fitted from above or below the ceiling Invisible once fan / vent is fitted 80mm and 100mm diameter sizes available |
![]() |
||||||||||||||||
| Description Recessed ceiling fans and ventilation ducts are widely used in both domestic and commercial buildings and the use of forced / controlled ventilation is increasing because it can be more energy efficient than traditional ventilation methods. Centralised ventilation units and heat recovery units result in a building having both horizontal and vertical penetration holes through the structure, creating pathways for the passage of fire and smoke. Once a hole is made in the ceiling for a polymeric fan or vent, the integrity of the construction and its ability to perform in a fire is reduced significantly. Ceilings subject to fire regulations must be fire protected in accordance with Approved Document B of the Building Regulations. Any vent opening must be fire stopped to reinstate the original fire rating of the ceiling. Unlike down lights, which are generally all fire protected, fans and vents are often left unprotected. A 100mm diameter fan or vent has several times the open area of a down light and lacks a metal “can” to slow the spread of fire. This, coupled with the ability of the fire to move all around the building via the ventilation system, makes it ever more important to fire protect ceiling mounted fans and vents.
Availability
| |||||||||||||||||
| Packing All sizes - 10 per pack
To Order & Specify Please quote : QTY / TRADENAME / PRODUCT REF / SIZE Typical wording 10 / ASTRO ACOUSTIC VENT SLEEVE AFAVS100
Fire Test or Assessment Reports Tested to the principles of BS 476 part 20 30 Minute Plasterboard / Timber Ceiling Health and Safety See COSHH Sheet.
Installation Please refer to our install sheet As part of our policy of ongoing improvements,
we reserve the right to modify, alter or change product specifications
without giving notice. Product illustrations are representations only.
All information contained in this document is provided for guidance
only, and as ASTROFLAME FIRESEALS LTD has no control over the installation
methods of the products, or of the prevailing site conditions, no warranties
expressed or implied are intended to be given as to the actual performance
of the products mentioned or referred to, and no liability whatsoever
will be accepted for any loss, damage or injury arising from the use
of the information given of products mentioned or referred to herein.
The above information to the best of our knowledge is true and accurate and based upon current test data and is supplied for your guidance only. Customers should satisfy themselves to the suitability of the product in its intended use and no guarantee is given or implied since the conditions of actual use are beyond our control. ASTROflame (Fireseals) Ltd, disclaim any liability for loss, damage or other expense arising from the use of information, data or products mentioned or referred to and reserve the right to change any details or specifications without notice.
|
|||||||||||||||||