Improves cladding performance
|
||||||||||||||||
| Description Many rainscreen and cladding systems are designed with an open cavity to provide back ventilation. The cavity acts like an open chimney to allow for moisture dissipation and to create a back pressure to repel rain ingress.
Ventilated Fire Barriers for Cavities 15mm - 50mm
Many timber framed structures require a continuous ventilated to be maintained to dissipate moisture and prevent damp problems. The Astroflame ventilated fire barriers have been tested in combustible timber constructions and can maintain the minimum 30 minute rating whilst allowing continuous ventilation in normal conditions.
Astro Clad – AFFRCLAD35 Astro Clad – AFFRCLAD35 was designed to meet the NHBC requirements to maintain a minimum 15mm ventilation gap in timber frame constructions. The product has been successfully fire tested in maximum size cavities of 25mm fitted directly onto combustible breather membrane and fixed into the timber structure to provide at least 30 minutes fire rating. It can additionally achieve greater fire ratings in non-combustible structures.
Fire ratings:
Astro Clad – AFFRCLAD75
The product has been successfully fire tested in cavities up to a maximum of 50mm within both combustible timber structures and non-combustible structures to provide up to 120 minutes fire rating.
Ventilated Fire Barriers for Cavities up to & over 125mmAstro Clad – AFFRCLAD5050 Astro Clad – AFFRCLAD5050 was designed to provide a large continuous open air space for cavities up to 125mm. ![]() The product has been successfully fire tested to a maximum cavity size of 125mm fitted directly onto combustible breather membrane and fixed into the timber structure to provide at least 30 minutes fire rating.
In addition the ventilated fire barrier can be fitted in between phenolic insulation to provide an effective fire barrier.
To order: Astro Clad – AFFRCLADPLUS+ Astro Clad-AFFRCLADPLUS+ offers an effective fire barrier for cavities over 125mm. The product has been successfully fire tested for up to 90 minutes fitted directly onto cement board.
The product not only offers a superior fire rating but also allows a continuous ventilation space of up to 44mm. This provides excellent ventilation behind the cladding whilst leaving enough free space for the installer to easily install the cladding panels after the ventilated fire barrier seal. Finish:
To order & specify Quote: Quantity /Trade name/Product ref Typical wording: 10/ASTRO CLAD / AFFRCLAD35 Health and Safety See COSHH Sheet. Installation Please refer to our install sheet
|
|||||||||||||||||
As part of our policy of ongoing improvements, we reserve the right to modify, alter or change product specifications without giving notice. Product illustrations are representations only. All information contained in this document is provided for guidance only, and as ASTROFLAME FIRESEALS LTD has no control over the installation methods of the products, or of the prevailing site conditions, no warranties expressed or implied are intended to be given as to the actual performance of the products mentioned or referred to, and no liability whatsoever will be accepted for any loss, damage or injury arising from the use of the information given of products mentioned or referred to herein. The above information