ASTROFLAME AIR TRANSFER
PLATES |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Introduction The purpose of this document is to give guidance to approved contractors and suppliers who are engaged in the fire stopping of service penetrations in walls,doors and fire rated structures using the Astroflame air transfer plates and astro grille. All service holes through floors and compartment walls must be fire stopped to prevent the passage of fire, smoke and hot gases. The key points for intumescent passive fire protection products are :-
The Astroflame Air Transfer Plate system ASTROflame air transfer plate are Mild Steel louvered grilles designed
to satisfy all types of air transfer application in offices, shops, schools,
hospitals and many other commercial projects. Manufactured using modern
press machinery and production techniques the ASTROflame air transfer
plate are robustly fabricated from 2Oswg mild steel and comprises of horizontal
louvres set on an 8.5mm pitch with a 30% downward deflection. Suitable for surface mounting in both door and wall mounting applications, the steel construction ensures that the unit is satisfactory not only forASTROflame Intumescent Fire Grilles but can also be used in standard air transfer applications, utilised with the wide flange border providing adequate clearance for fixing to the surrounding structure. Slimline and unobtrusive the unit offers a free area around 70% for economical selection and is readily available in a wide variety of sizes. Standard finish is Satin Aluminium .
Dimensional Data
Flange screw fixing using self tapping screws provided. Compliance
Testing certification Astroflame air transfer plate has been tested in conjunction with the astro fire grille to achieve in excess of 60min rating. On its own the transfer plate has no rating but can be used to give an aesthetically pleasing finish to any hole requiring a transfer of air.
Storage and disposal Astroflame air transfer plates are to be stored indoors in normal room
temperatures. No shelf life is given as this product will not deteriorate
in storage. For additional testing, certification or technical information please
contact ASTROFLAME FIRESEALS LTD. Issue 01/03 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
As part of our policy of ongoing improvements,
we reserve the right to modify, alter or change product specifications without
giving notice. Product illustrations are representations only. All information
contained in this document is provided for guidance only, and as ASTROFLAME
FIRESEALS LTD has no control over the installation methods of the products,
or of the prevailing site conditions, no warranties expressed or implied are
intended to be given as to the actual performance of the products mentioned
or referred to, and no liability whatsoever will be accepted for any loss, damage
or injury arising from the use of the information given of products mentioned
or referred to herein.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||