Intumescent Fire/Smoke & Acoustic Telescopic Letterbox System
|
|||||||||||||||
Introduction The purpose of this document is to give guidance to approved contractors and suppliers who are engaged in the fire stopping of fire rated structures using the Astro Telescopic Letter Box System. All fire door assemblies must be fire stopped to prevent the passage of fire, smoke and hot gases and must maintain their integrity through out the life of the door. The key points for passive fire protection products are :- Prevent the spread of fire, smoke and hot gases through a building by containing it in the compartment of origin Maintain the integrity of escape routes from a building. Reduce loss or damage to property from the effect of fire and smoke. Maintain pressure differential between compartments and ventilation channels. |
|||||||||||||||
|
The Astro Telescopic Letter Box The Astroflame telescopic letter box system range is specially designed to increase the safety and security of occupants against fire, Smoke and Sound Pollution. The range includes models which are fire-rated from 30 minutes to 1 hour. Where relevant, particularly for multiple occupancy residential buildings, letterboxes have been fire and smoke-seal tested to BS 476 PART 22 for 30 or 60 minutes fire rating. Our fire & smoke telescopic letter box also carries an Acoustic rating to 29db/Rw sound reduction criteria as outlined in Approved Document E for door sets. Tested to BS EN SO 140, Tested to BS EN 20140-10. Standard lengths 2100mm - Longer lengths up to 3m to order.
|
|||||||||||||||
|
Installation
Mark out sleeve and fixing holes
![]() Drill and saw or rout sleeve hole using a 25mm Max router/drill Drill fixing holes 8mm Max
Assemble letterplate into position ensuring hexagonal fixing screw is on the inside of the door
Tighten hexagonal fixing screws using 2.5mm key
|
|||||||||||||||
|
Compliance Astro Telescopic Letter Box are manufactured in the EU, meeting the highest quality standard in compliance with ISO EN 9001:2000 . For fire test certification contact Astroflame Fireseals technical department. Fire Tests Certifire Approved- CF 255 Tested to BS 476 PART 22 for 30 or 60 minutes fire rating Tested to BS EN ISO140 to 29db/Rw for acoustic rating Storage and disposal Astro Telescopic Letter Box should be stored indoors. No shelf life is given as this product will not deteriorate in storage. For additional testing, certification or technical information please contact ASTROFLAME FIRESEALS LTD. Issue 01/06 |
|||||||||||||||
As part of our policy of ongoing improvements,
we reserve the right to modify, alter or change product specifications
without giving notice. Product illustrations are representations only.
All information contained in this document is provided for guidance
only, and as ASTROFLAME FIRESEALS LTD has no control over the installation
methods of the products, or of the prevailing site conditions, no warranties
expressed or implied are intended to be given as to the actual performance
of the products mentioned or referred to, and no liability whatsoever
will be accepted for any loss, damage or injury arising from the use
of the information given of products mentioned or referred to herein.
The above information to the best of our knowledge is true and accurate and based upon current test data and is supplied for your guidance only. Customers should satisfy themselves to the suitability of the product in its intended use and no guarantee is given or implied since the conditions of actual use are beyond our control. ASTROflame (Fireseals) Ltd, disclaim any liability for loss, damage or other expense arising from the use of information, data or products mentioned or referred to and reserve the right to change any details or specifications without notice.
|
|||||||||||||||