Astroflame Homepage

 

Astroflame Product Installation Guide


Telescopic Letterboxes - Installation Guide

Fire Smoke & Acoustic Rated Letterbox

 

Introduction

The purpose of this document is to give guidance to approved contractors and suppliers who are engaged in the fire stopping of fire rated structures using the Astro Telescopic Letter Box System.

 

The Astro Telescopic Letter Box

The Astroflame telescopic letter box system range is specially designed to increase the safety, and comfort of occupants against Fire, Smoke and Noise.

The range includes models which are:

fire and smoke rated for 30 minutes

fire rated for 60 mins

fire rated for 60mins with additional smoke and acoustic rating.

Where relevant, particularly for multiple occupancy residential buildings, letterboxes have been fire and smoke-seal tested to BS 476 PART 22 for 30 or 60 minutes fire rating.

Our FAS Telescopic Letterbox (fire, smoke and acoustic rated) has an acoustic rating or Rw 29dB - as outlined in Approved Document E for door sets.

Tested to BS EN SO 140, Tested to BS EN 20140-10.

 

Telescopic Letterbox Installation

 

Tape template provided to door face checking it is centred and level.

Mark out sleeve and fixing holes

 

 

 

Drill and saw or rout sleeve hole using a 25mm Max router/drill

Drill fixing holes 8mm Max

 

 

 

Assemble letterplate into position ensuring hexagonal fixing screw is on the inside of the door

 

 

 

 

 

 

Tighten hexagonal fixing screws using 2.5mm key

 

 

 

Compliance

Astro Telescopic Letter Box are manufactured in the EU, meeting the highest quality standard in compliance with ISO EN 9001:2000 . For fire test certification contact Astroflame Fireseals technical department.

Fire Tests

Certifire Approved- CF 255

Tested to BS 476 PART 22 for 30 or 60 minutes fire rating

Tested to BS EN ISO140 to 29db/Rw for acoustic rating

Storage and disposal

Astro Telescopic Letter Box should be stored indoors. No shelf life is given as this product will not deteriorate in storage.

For additional testing, certification or technical information please contact ASTROFLAME FIRESEALS LTD.

Issue 01/06

 
Astroflame (Fire Seals) Ltd. Intumescent House
Unit 8, The IO Centre, Stephenson Road, Segensworth
FAREHAM, ENGLAND PO15 5RU
tel 0800 023 2482
(01329 844500)
fax 0800 023 2483
(01329 844600)
intl
tel +44 1329 844500
fax +44 1329 844600