THRESHOLD SMOKE SEALS |
![]() |
||||||||||||||||
| Raven Seals have been designed to accomodate a variety of duty levels, classified on this web site as light, medium and heavy. L Light Duty seals include those typically used in resedential applications or light traffic areas. M Medium Duty seals are used in commercial applications such as office spaces, shops, commercial accomodation or medium traffice areas. H Heavy Duty seals are designed for areas with a high level of use such as public places such as hospitals, airports, factories, shopping centres or areas with a large flow through of pedestrian and wheeled traffic. |
|||||||||||||||||
|
|
A threshold plate seal particularly suited for outward opening broad butt hinged plant room and emergency exit doors. When used in conjunction with RP93si and RP93si an excellent smoke and acoustic system is achieved. For acoustic applications the void under the RP97si should be filled with sound proof foam or other suitable materials (by others). Note: RP67 drip cap should be considered above doorway if opening has no eave weather protection. Specify order length wider than door opening to provide a neat detail at door frame.
|
||||||||||||||||
![]() |
|||||||||||||||||
| Location door seals abutting outward opening broad butt hinged plant or emergency exit doors. Not recommended for pedestrian entry doors. Min/max compression of seal 0mm/2mm. Seal Lengths 250mm increments to 5000mm Standard finish Anodised satin clear or bronze. Fixing method Zinc plated , cross recess head CSK S.T. screws of the appropriate size and colour are supplied, or can be fastened with builders adhesive for concealed fixing (user determined). Seal material Replacement seal RP393si
|
|||||||||||||||||
|
|
The RP117Si is a weather proof threshold plate seal suited to outward opening broad butt hinged doors. Its ideal for use with a panic type exit device (by others). For acoustic applications the void under the threshold should be filled with sound foam or other suitable materials - Astro FR Acoustic Foam
|
||||||||||||||||
![]() |
|||||||||||||||||
| Location Seal Sizes Standard Finish Fixing Method Used in conjunction Seal Material Replacement Seal RP308Si. Approvals
|
|||||||||||||||||
As part of our policy of ongoing improvements,
we reserve the right to modify, alter or change product specifications
without giving notice. Product illustrations are representations only.
All information contained in this document is provided for guidance
only, and as ASTROFLAME FIRESEALS LTD has no control over the installation
methods of the products, or of the prevailing site conditions, no warranties
expressed or implied are intended to be given as to the actual performance
of the products mentioned or referred to, and no liability whatsoever
will be accepted for any loss, damage or injury arising from the use
of the information given of products mentioned or referred to herein.
The above information to the best of our knowledge is true and accurate and based upon current test data and is supplied for your guidance only. Customers should satisfy themselves to the suitability of the product in its intended use and no guarantee is given or implied since the conditions of actual use are beyond our control. ASTROflame (Fireseals) Ltd, disclaim any liability for loss, damage or other expense arising from the use of information, data or products mentioned or referred to and reserve the right to change any details or specifications without notice.
|
|||||||||||||||||
|
|||||||||||||||||