| Easy to install putty pad alternative Tested to BS 476 Part 20 for up to 120 minutes. Prevents or delays fire from entering a wall cavity
and attacking the building structure.
|
|
||||||||
| Description The use of recessed switch and socket boxes in walls is widespread in private, public and commercial buildings. The walls are subject to fire regulations and most will have to be fire rated. Once a hole is made in the wall for a recessed switch or socket box, the fire integrity of the construction is compromised: in addition the ability for the wall to provide an effective acoustic barrier is also impaired. For timber framed buildings preventing a fire from entering wall cavities and attacking the structure is critical to the overall fire integrity of the building.
These intumescent covers have been developed to provide maximum protection for wall penetrations created by the introduction of single and double recessed switch / socket boxes. Easy to fit they restore and maintain fire insulation and integrity in plasterboard walls for up to 120 minutes. In a fire situation, the cover expands internally to fill all of the available space with a fire resistant highly insulating char. The fire is unable to penetrate the hole and the cover is able to give additional insulation protection to the wall void by reducing the chance of heat build up and the ignition of flammable structural members. The penetration in the wall also provides a path for air (creating heat loss and drafts) and noise transmission - fitting an ASTRO FRA Socket Box Cover reduces these problems. The one-piece socket box is designed for most common single & double electrical boxes. In a wall with two layers of plasterboard on each face, the ends of the fixing wires can be pushed between the plasterboard layers. Availability Single or Double Socket sizes / one per box or boxes of 10 per size Single size cover dimensions: 90mm x 90mm x 50mm deep To order & specify Please quote : QTY / TRADE NAME / SIZE / PRODUCT REF
Fire Test and Assessment Reports ASTRO FRA Socket Box Covers have been tested to BS476 part 20 in an un-insulated
plasterboard wall construction for 120 minutes without failure in either
insulation or integrity. Health and Safety See COSHH Sheet. Installation Please refer to our install sheet For additional testing, or technical information please contact ASTROFLAME FIRESEALS LTD.
|
|||||||||
|
Related Documents |
|||||||||
As part of our policy of ongoing improvements, we reserve the right to modify, alter or change product specifications without giving notice. Product illustrations are representations only. All information contained in this document is provided for guidance only, and as ASTROFLAME FIRESEALS LTD has no control over the installation methods of the products, or of the prevailing site conditions, no warranties expressed or implied are intended to be given as to the actual performance of the products mentioned or referred to, and no liability whatsoever will be accepted for any loss, damage or injury arising from the use of the information given of products mentioned or referred to herein.
|
|||||||||
![]() |
|||||||||
|
|||||||||